 Agilent N4374B 4.5 GHz Single-Mode Lightwave Component Analyzer for CATV and Radio over Fiber
Data Sheet
www..com
General Information
Agilent's N4374B Lightwave Component Analyzer (LCA) is optimized for the electro-optical S-parameter measurement for Cable TV (CATV) and Radio over Fiber (RoF) or radio frequency over Glass (RFoG) applications. In modern CATV or RoF/RFoG transmission systems analog signals are directly transmitted over optical fiber. This requires very low distortion of the electro-optical devices at the transmitter and the receiver side. Therefore it is necessary to have very flat transfer characteristic in amplitude and delay. The N4374B LCA is the tool of choice to optimize your design for these parameters. For frequency dependent responsivity measurements the N4374B is the successor of the industry standard 8702 LCA series. It supports 75 Ohm test with a minimum loss pad (MLP). With a completely new design of the optical test set together with the newest ENA based network analyzer, the N4374B guarantees excellent electro-optical measurement performance. It's the excellent accuracy that improves the yield from tests performed with the N4374B, by narrowing margins needed to pass the tested devices. NIST traceability ensures worldwide comparability of test results. The fully integrated "turnkey" solution reduces time to market, compared to the time-consuming development of a selfmade setup. In addition a unique new calibration concept significantly reduces time from powering up the LCA until the first calibrated measurement can be made. This increases productivity in R&D and on the manufacturing floor. By optimizing the electrical and optical design of the N4374B for lowest noise and ripple, the accuracy has been improved by more than a factor of 5 compared to the 8702 series LCA and is now independent of the electrical reflection coefficient of the device under test. The advanced optical design together with temperaturestabilized transmitter and receiver ensures repeatable measurements over days without recalibration. Using the advanced measurement capabilities of the network analyzer, all S-parameter related characteristics of the device under test, like responsivity, ripple, group delay and 3dB-cutoff frequency, can be qualified with the new N4374B www..com Lightwave Component Analyzer from 100kHz to 4.5 GHz.
Key benefits
High absolute and relative accuracy measurements improve the yield of development and production processes. With the excellent accuracy and reproducibility, measurement results can be compared among test locations world wide. High confidence and fast time-to-market with a NISTtraceable turnkey solution. Significantly increased productivity using the fast and easy measurement setup with a unique new calibration process leads to lower cost of test. 75 Ohm support Specified phase uncertainty More than 5 times faster than predecessor 8702 series speeds up every test procedure Identical LCA software and remote control across the N437xB family simplifies integration Bias-T included in Network Analyzer Relative frequency response uncertainty: 0.6 dB @ 4.5GHz (typ) Absolute frequency response uncertainty: 1.3 dB @ 4.5GHz (typ) Noise floor: -103 dB W/A for E/O measurements @ 4.5 GHz -90 dB A/W for O/E measurements @ 4.5 GHz Typical phase uncertanty: 1.5 max Transmitter wavelength: 1550nm 20 nm 1310nm 20 nm 1290 - 1610 nm with external source input Built-in optical power meter For fast transmitter power verification Powerful remote control: State of the art programming interface based on Microsoft .NET or COM. Warranty: 1 year warranty is standard for N4374B Lightwave Component Analyzer. Extension to 3 or 5 years available.
The network analyzer
The N4374B is based on the newest E5071C ENA network analyzer series. The network analyzer includes a Bias-T for biasing the electro-optical components.
2
Agilent N4374B Applications
In photonic CATV or RoF transmission systems, it is necessary to design and qualify subcomponents like direct modulated lasers and receivers, which are analog by nature, with different parameters. Those parameters are core to the overall system performance. These electro-optical components significantly influence the overall performance of the transmission system via the following parameters: 3dB bandwidth of the electro-optical transmission Relative frequency response, quantifying the electrooptical shape of the conversion. Absolute frequency response, relating to the conversion efficiency of signals from the input to the output, or indicating the gain of a receiver. Electrical reflection at the RF port Group delay of the electro-optical transfer function Only a careful design of these electro-optical components over a wide modulation signal bandwidth guarantees successful operation in the transmission system.
Agilent N4374B Features
Turnkey solution
In today's highly competitive environment, short time-tomarket with high quality is essential for new products. Instead of developing a home-grown measurement solution which takes a lot of time and is limited in transferability and support, a fully specified and supported solution helps to focus resources on faster development and on optimizing the manufacturing process. In the N4374B all optical and electrical components are carefully selected and matched to each other to minimize noise and ripple in the measurement traces. Together with the temperature stabilized environment of the core components, this improves the repeatability and the accuracy of the overall system. Extended factory calibration data at various optical power levels ensures accurate and reliable measurements that can only be achieved with an integrated solution like the N4374B.
Easy calibration
An LCA essentially measures the conversion relation between optical and electrical signals. This is why user calibration of such systems can evolve into a time consuming task. With the new calibration process implemented in the N4374B, the tasks that have to be done by the user are reduced to one pure electrical calibration. The calibration with an electrical calibration module is automated and needs only minimal manual interaction. With the minimum loss pad (MLP) which is part of the LCA shipment the impedance match from 50 Ohm LCA system to 75 Ohm test device can be realized in an easy way. The correction for the 75 Ohm impedance is enabled with one button in the LCA software which uses default data to correct the MLP transfer behavior. For higher accuracy an individual calibration of the MLP can be realized with the adaptor removal tool which is part of each ENA-C
Electro-optical components
The frequency response of amplified or unamplified detector diodes, modulators and directly modulated lasers typically depends on various parameters, like bias voltages, optical input power, operating current and ambient temperature. To determine the optimum operating point of these devices, an LCA helps by making a fast characterization of the electrooptic transfer function while optimizing these operating conditions. In parallel the LCA also measures the electrical return loss. In manufacturing it is important to be able to monitor the processes regularly to keep up the throughput and yield. In this case the LCA is the tool of choice to monitor transmission characteristics and absolute responsivity of the manufactured device. The remote control of the N4374B offers another tool to improve the productivity by making automated measurements and analysis of the measured data.
Built-in performance verification
Sometimes it is necessary to make a quick verification of the validity of the calibration and the performance of the system. The N4374B's unique calibration process allows the user to perform a self-test without external reference devices. This gives full confidence that the system performance is within the user's required uncertainty bands.
Electrical components
Electrical components such as amplifiers, filters and transmission lines are used in modern transmission systems and require characterization to ensure optimal performance. Typical measurements are bandwidth, insertion loss or gain, impedance match and group delay. The new switched architecture offers direct access to the electrical outputs and inputs of the network-analyzers just by selecting electrical- to www..com electrical measurement mode in the LCA user interface.
3
State-of-the-art remote control
Testing the frequency response of electro-optical components under a wide range of parameters, which is often necessary in qualification cycles, is very time consuming. To support the user in minimizing the effort for performing this huge number of tests, all functions of the LCA can be controlled remotely via LAN over the state-of-the-art Microsoft .NET or COM interface. This interface is identical for all LCA of the N437xB/C series. Based on programming examples for VBA with Excel, Agilent VEE and C++, it is very easy for every user to build applications for their requirements. These examples cover applications like integration of complete LCA measurement sequences.
Integrated optical power meter
In applications where optical power dependence characterization is needed, the average power meter can be used to set the exact average output power of the LCA transmitter by connecting the LCA optical transmitter output, optionally through an optical attenuator, to the LCA optical receiver input. By adjusting the transmitter output power in the LCA user interface or the optical attenuation, the desired transmitter optical power can be set. In cases where an unexpectedly low responsivity is measured from the device under test, it is very helpful to get a fast indication of the CW optical power that is launched into the LCA receiver. The cause might be a bad connection or a bent fiber in the setup. For this reason too, a measurement of the average optical power at the LCA receiver is very helpful for fast debugging of the test setup.
Selectable output power of the transmitter
Most PIN diodes and receiver optical subassemblies need to be characterized at various average optical power levels. In this case it is necessary to set the average input power of the device under test to the desired value. The variable average optical output power of the LCA transmitter offers this feature. Together with an external optical attenuator, this range can be extended to all desired optical power levels.
Group delay and length measurements
In some applications it is necessary to determine the electrical or optical length of a device. With the internal length calibration of the electro-optical paths with reference to the electrical and optical inputs or outputs, it is possible to determine the length of the device under test
External optical www..com
source input
For applications where test of opto-electric devices need to be done at a specific optical wavelength, the N4374B-050 offers an external optical input to the internal modulator where an external tunable laser can be applied. As modulators are polarization sensitive devices, this input is a PMF input to a PMF optical switch to maintain the polarization at the internal modulator.
4
Definitions
Generally, all specifications are valid at the stated operating and measurement conditions and settings, with uninterrupted line voltage.
Explanation of terms
Responsivity
For electro-optical devices (e.g. modulators ) this describes the ratio of the optical modulated output signal amplitude compared to the RF input amplitude of the device. For opto-electrical devices (e.g. photodiodes) this describes the ratio of at the RF amplitude at the device output to the amplitude of the modulated optical signal input. .
Specifications (guaranteed)
Describes warranted product performance that is valid under the specified conditions. Specifications include guard bands to account for the expected statistical performance distribution, measurement uncertainties changes in performance due to environmental changes and aging of components.
Relative frequency response uncertainty
Describes the maximum deviation of the shape of a measured trace from the (unknown) real trace. This specification has strong influence on the accuracy of the 3-dB cut-off frequency determined for the device under test.
Typical values (characteristics)
Characteristics describe the product performance that is usually met but not guaranteed. Typical values are based on data from a representative set of instruments.
Absolute frequency response uncertainty
Describes the maximum difference between any amplitude point of the measured trace and the (unknown) real value. This specification is useful to determine the absolute responsivity of the device versus modulation frequency.
General characteristics
Give additional information for using the instrument. These are general descriptive terms that do not imply a level of performance.
Frequency response repeatability
Describes the deviation of repeated measurement without changing any parameter or connection relative to the average of this measurements.
Minimum measurable frequency response
Describes the average measured responsivity when no modulation signal is present at the device under test. This represents the noise floor of the measurement system.
Definition of LCA input and output names
www..com
LCA electrical port A
LCA electrical port B
LCA optical output
LCA optical input
5
Measurement capabilities
3dB cut-off frequency (S21), Responsivity (S21), Electrical reflection (S11 or S22), Group Delay vs. frequency, Insertion Loss (IL), Transmission bandwidth, all electrical S-parameter measurements. Target test devices Transmitter (E/O)
Agilent N4374B Specifications
Measurement conditions Modulation frequency range from 10 MHz to 4.5 GHz Foreward and reverse RF power +5 dBm Number of points 899 Number of averages: 1 IFBW 300 Hz Network analyzer set to "stepped sweep - sweep moves in discrete steps" After full two-port electrical calibration using an Electronic Calibration Module, Agilent 85092C, at constant temperature (1 C) Modulator bias optimization set to "every sweep" Measurement frequency grid equals electrical calibration grid DUT signal delay 0.1/IF-BW Specified temperature range: +20 C to +26 C. After warm-up time of 90 minutes Using high quality electrical and optical connectors and RF cables in perfect condition Using supplied RF cables (8120-8862)
Receiver (O/E) PIN diodes Avalanche photodiodes (APD) Receiver optical subassemblies (ROSA) Optical (O/O) Passive optical components Optical fibers and filters Optical transmission systems
www..com
6
Transmitter and Receiver Specifications
Optical Test set Operation frequency range Connector type optical input optical output optical source input (rear) RF LCA optical input Operating input wavelength range Maximum linear average input power [f1] Maximum safe average input power Optical return loss (typ.) [f1] Average power measurement range
[f1]
Option -332, -362 100 kHz to 4.5 GHz SMF angled with Agilent versatile connector interface PMF angled, with Agilent versatile connector interface, polarization orientation aligned with connector key N type, female
1250 nm to 1640 nm [f4] Optical input 1: Optical input 2: Optical input 1: Optical input 2: > 27 dBo Optical input 1: Optical input 2: 0.5 dBo -25 dBm to +4 dBm on optical input 1 -15 dBm to +14 dBm on optical input 2 +4 dBm +14 dBm +7 dBm +17 dBm
Average power measurement uncertainty (typ.) [f1] LCA optical output (internal source) Optical modulation index (OMI) at 1 GHz (typ.) Output wavelength Average output power range Average output power uncertainty (typ.) Average output power stability, 15 minutes (typ.)
[f2]
> 30 % @ +5 dBm RF power option -100, -102 (1310 20) nm option -101, -102 (1550 20) nm -2 dBm to +4 dBm 0.5 dBo 0.5 dBo
External optical source input (-050) Optical input power range for typical performance Optical input damage level Typical loss at quadrature bias point Operating input wavelength range +8 dBm to +15dBm +20 dBm 9 dB 1290 nm to 1640 nm [f4]
LCA RF test port input Maximum safe input level at port A or B
www..com
+15 dBm RF, 7V DC
[f1] Wavelength within range as specified for LCA optical output [f2] After modulator optimization [f3] Required source characteristics: SMSR : >35 dB, line width <10 MHz, power stability < 0.1 dB, PER > 20dB, unmodulated, single mode [f4] Excluding water absorption wavelength
7
Specifications for electro-optical measurements at 1310 nm
N4374B system with network analyzer E5071C -245
(E/O mode)
Specifications are valid under the stated measurement conditions. At optical input 1 ("+ 7 dBm max"). At optical input 2 ("+ 17 dBm max"), specifications are typically the same for 10 dB higher incident average and modulated optical power. For wavelength: (1310 20) nm (option -100, 102). System performance Relative frequency response uncertainty DUT response -18 dB(W/A) [f1] 0.5 dBe typ. -38 dB(W/A) Absolute frequency response uncertainty Frequency response repeatability (typ.) DUT response -18 dB(W/A) [f1] 1.3 dBe typ DUT response -38 dB(W/A) [f1] 0.02 dBe -98 dB(W/A) typ. 0.02 dBe -103 dB(W/A) 0.02 dBe -103 dB(W/A) 2.2 dBe (1.3 dBe typ.) 2.2 dBe (1.3 dBe typ.) 0.5 dBe typ. 0.7 dBe (0.5 dBe typ.) 0.5 dBe typ 0.8 dBe (0.6 dBe typ.) 0.6 dBe typ. 10 MHz to 50 MHz 50 MHz to 0.7 GHz 0.7 GHz to 4.5 GHz
Minimum measurable frequency response (noise floor ) [f2] [f4] Phase uncertainty (typ.) [f3] Group delay uncertainty DUT response -38 dB(W/A) [f1]
-
1.5
1.5
Derived from phase uncertainty, see section "Group delay uncertainty". Example: 1.0 8 ps (0.5 GHz aperture)
[f1] For DUT optical peak output power +7 dBm. [f2] IFBW = 100 Hz. [f3] Except phase wrap aliasing (example: a DUT group delay of 5 ns (1 m cable length) requires a frequency step size of 0.2 GHz to avoid phase wraps). Excluding a constant group delay offset of <0.3 ns typ. (cable length uncertainty < 0.06 m). A constant group delay offset leads to a phase offset = 360 x GD x fmod (in deg). [f4] Average value over frequency range
www..com
8
Specifications for electro-optical measurements at 1550 nm
N4374B system with network analyzer E5071C -245
(E/O mode)
Specifications are valid under the stated measurement conditions. At optical input 1 ("+ 7 dBm max"). At optical input 2 ("+ 17 dBm max"), specifications are typically the same for 10 dB higher incident average and modulated optical power. For wavelength: (1550 20) nm (option -101, 102). System performance Relative frequency response uncertainty DUT response -18 dB(W/A) [f1] 0.5 dBe typ. -38 dB(W/A) Absolute frequency response uncertainty Frequency response repeatability (typ.) DUT response -18 dB(W/A) [f1] 1.3 dBe typ DUT response -38 dB(W/A) [f1] 0.02 dBe -100 dB(W/A) typ. 0.02 dBe -103 dB(W/A) 0.02 dBe -103 dB(W/A) 2.2 dBe (1.3 dBe typ.) 2.2 dBe (1.3 dBe typ.) 0.5 dBe typ. 0.7 dBe (0.5 dBe typ.) 0.5 dBe typ 0.8 dBe (0.6 dBe typ.) 0.6 dBe typ. 10 MHz to 50 MHz 50 MHz to 0.7 GHz 0.7 GHz to 4.5 GHz
Minimum measurable frequency response (noise floor ) [f2] [f4] Phase uncertainty (typ.) [f3] Group delay uncertainty DUT response -38 dB(W/A) [f1]
-
1.0
1.0
Derived from phase uncertainty, see section "Group delay uncertainty". Example: 1.0 8 ps (0.5 GHz aperture)
[f1] For DUT optical peak output power +7 dBm. [f2] IFBW = 100 Hz. [f3] Except phase wrap aliasing (example: a DUT group delay of 5 ns (1 m cable length) requires a frequency step size of 0.2 GHz to avoid phase wraps). Excluding a constant group delay offset of <0.3 ns typ. (cable length uncertainty < 0.06 m). A constant group delay offset leads to a phase offset = 360 x GD x fmod (in deg). [f4] Average value over frequency range.
www..com
9
Specifications for opto-electrical measurements at 1310 nm
N4374B system with network analyzer E5071C -245
(O/E mode)
Specifications are valid under the stated measurement conditions. With external optical source input all specifications are typical [f2][f6][f7] For wavelength: (1310 20) nm (option -100, 102) System performance Relative frequency response uncertainty[f2] DUT response -36 dB(A/W) [f1] 0.5 dBe typ. -46 dB(A/W) Absolute frequency response uncertainty Frequency response repeatability (typ.) [f2] DUT response -36 dB(A/W) [f1] 1.2 dBe typ DUT response -46 dB(A/W) [f1] 0.02 dBe -83 dB(A/W) typ. 0.02 dBe -92 dB(A/W) 0.03 dBe -92 dB(A/W) 1.8 dBe (1.2 dBe [f8] ) 1.8 dBe (1.2 dBe [f8] ) 0.5 dBe typ. 0.7 dBe (0.5 dBe [f8] ) 0.5 dBe typ. 0.8 dBe (0.6 dBe [f8] ) 0.6 dBe typ. 10 MHz to 50 GHz 50 MHz to 0.7 GHz 0.7 GHz to 4.5 GHz
Minimum measurable frequency response (noise floor ) [f2] [f3] [f5] Phase uncertainty (typ.) [f2][f4] Group delay uncertainty DUT response -36 dB(A/W) [f1]
-
1.0
1.0
Derived from phase uncertainty, see section "Group delay uncertainty". Example: 1.0 8 ps (0.5 GHz aperture)
[f1] [f2] [f3] [f4] [f5] [f6] [f7] [f8]
For DUT response max. +10 dB (A/W). For +4 dBm average output power from LCA optical output IFBW = 100 Hz. Except phase wrap aliasing (example: a DUT group delay of 5 ns (1 m cable length) requires a frequency step size of 0.2 GHz to avoid phase wraps). Excluding a constant group delay offset of <0.3 ns typ. (cable length uncertainty <0.06 m). A constant group delay offset leads to a phase offset = 360 x GD x fmod.(in deg). Average value over frequency range. After CW responsivity and user calibration with external source. Requires option -100 or -102. Typical with internal source.
www..com
10
Specifications for opto-electrical measurements at 1550 nm
N4374B system with network analyzer E5071C -245
(O/E mode)
Specifications are valid under the stated measurement conditions. With external optical source input all specifications are typical [f2][f6][f7] For wavelength: (1550 20) nm (option -101, 102) System performance Relative frequency response uncertainty[f2] DUT response -36 dB(A/W) [f1] 0.5 dBe typ. -46 dB(A/W) Absolute frequency response uncertainty Frequency response repeatability (typ.) [f2] DUT response -36 dB(A/W) [f1] 1.2 dBe typ DUT response -46 dB(A/W) [f1] 0.02 dBe -83 dB(A/W) typ. 0.02 dBe -92 dB(A/W) 0.03 dBe -90 dB(A/W) 2.0 dBe (1.2 dBe [f8] ) 2.1 dBe (1.2 dBe [f8] ) 0.5 dBe typ. 0.7 dBe (0.5 dBe [f8] ) 0.5 dBe typ. 0.8 dBe (0.6 dBe [f8] ) 0.6 dBe typ. 10 MHz to 50 MHz 50 MHz to 0.7 GHz 0.7 GHz to 4.5 GHz
Minimum measurable frequency response (noise floor ) [f2] [f3] [f5] Phase uncertainty (typ.) [f2][f4] Group delay uncertainty DUT response -36 dB(A/W) [f1]
-
1.0
1.0
Derived from phase uncertainty, see section "Group delay uncertainty". Example: 1.0 8 ps (0.5 GHz aperture)
[f1] [f2] [f3] [f4] [f5] [f6] [f7] [f8]
For DUT response max. +10 dB (A/W). For +4 dBm average output power from LCA optical output IFBW = 100 Hz. Except phase wrap aliasing (example: a DUT group delay of 5 ns (1 m cable length) requires a frequency step size of 0.2 GHz to avoid phase wraps). Excluding a constant group delay offset of <0.3 ns typ. (cable length uncertainty <0.06 m). A constant group delay offset leads to a phase offset = 360 x GD x fmod.(in deg). Average value over frequency range. After CW responsivity and user calibration with external source. Requires option -101 or -102. Typical with internal source.
www..com
11
Specifications for optical to optical measurements at 1310 nm
N4374B system with networrk analyzer E5071C -245
(O/O mode)
Specifications are valid under the stated measurement conditions and after user calibration with LCA optical output set to maximum average power (+4 dBm) At optical input 1 ("+ 7 dBm max"). At optical input 2 ("+ 17 dBm max"), specifications are typically the same for 10 dB higher incident average and modulated optical power. With external optical source input all specifications are typical [f2][f6][f7] For wavelength: (1310 20) nm (option -100, 102). System performance Relative frequency DUT response response uncertainty[f2] -13 dBe ( -6.5 dBo) [f4] Absolute frequency DUT response response uncertainty[f2] -13 dBe [f4] ( -6.5 dBo) Frequency response repeatability (typ.) [f2] DUT response -13 dBe ( -6.5 dBo) [f4] 0.02 dBe -76 dBe typ. (-38 dBo) 0.02 dBe -82 dBe (-41 dBo) 0.5 0.02 dBe -80 dBe (-40 dBo ) 0.5 10 MHz to 50 MHz 0.25 dBe, (typ.) (0.125 dBo ), (typ.) . 1.0 dBe typ. (0.5 dBo typ.) 1.0 dBe (0.5 dBo) 1.0 dBe (0.65dBo) 50 MHz to 0.7 GHz 0.25 dBe (0.125 dBo) 0.7 GHz to 4.5 GHz 0.25 dBe (0.125 dBo)
Minimum measurable frequency response (noise floor ) [f1] [f3][f5] Phase uncertainty (typ.) [f2][f3] Group delay uncertainty DUT response -13 dBe (-6.5 dBo) [f4]
Derived from phase uncertainty, see section "Group delay uncertainty". Example: 1.0 8 ps (0.5 GHz aperture)
[f1] [f2] [f3] [f4] [f5] [f6] [f7]
IFBW = 100 Hz. For +4 dBm average output power from LCA optical output. Except phase wrap aliasing (example: a DUT group delay of 5 ns (1 m cable length) requires a frequency step size of 0.2 GHz to avoid phase wraps). For DUT response maximum +6 dBe ( +3dBo ) gain. Average value over frequency range. After CW responsivity and user calibration with external source. Requires option -100 or -102.
www..com
12
Specifications for optical to optical measurements at 1550 nm
N4374B system with networrk analyzer E5071C -245
(O/O mode)
Specifications are valid under the stated measurement conditions and after user calibration with LCA optical output set to maximum average power (+4 dBm) At optical input 1 ("+ 7 dBm max"). At optical input 2 ("+ 17 dBm max"), specifications are typically the same for 10 dB higher incident average and modulated optical power. With external optical source input all specifications are typical [f2][f6][f7] For wavelength: (1550 20) nm (option -101, 102). System performance Relative frequency DUT response response uncertainty[f2] -13 dBe ( -6.5 dBo) [f4] Absolute frequency DUT response response uncertainty[f2] -13 dBe [f4] ( -6.5 dBo) Frequency response repeatability (typ.) [f2] DUT response -13 dBe ( -6.5 dBo) [f4] 0.02 dBe -76 dBe typ. (-38 dBo) 0.02 dBe -82 dBe (-41 dBo) 0.5 0.02 dBe -80 dBe (-40 dBo ) 0.5 10 MHz to 50 MHz 0.25 dBe, (typ.) (0.125 dBo ), (typ.) 1.0 dBe typ. (0.5 dBo typ.) 50 MHz to 0.7 GHz 0.25 dBe (0.125 dBo) 1.0 dBe (0.5 dBo) 0.7 GHz to 4.5 GHz 0.25 dBe (0.125 dBo) 1.0 dBe (0.65dBo)
Minimum measurable frequency response (noise floor ) [f1] [f3][f5] Phase uncertainty (typ.) [f2][f3] Group delay uncertainty DUT response -13 dBe (-6.5 dBo) [f4]
Derived from phase uncertainty, see section "Group delay uncertainty". Example: 1.0 8 ps (0.5 GHz aperture)
[f1] [f2] [f3] [f4] [f5] [f6] [f7]
IFBW = 100 Hz. For +4 dBm average output power from LCA optical output. Except phase wrap aliasing (example: a DUT group delay of 5 ns (1 m cable length) requires a frequency step size of 0.2 GHz to avoid phase wraps). For DUT response maximum +6 dBe ( +3dBo ) gain. Average value over frequency range. After CW responsivity and user calibration with external source. Requires option -101 or -102.
www..com
13
Specifications for electrical-electrical measurements (E/E mode)
All specifications of the E5071C -245 Network Analyzer apply. Please see the corresponding Network Analyzer data sheet and User's Guide
Group delay uncertainty
For more details see specifications of the E5071C. Group delay Group delay is computed by measuring the phase change within a specified aperture (for aperture see below. Phase change [deg] ----------------------------------------Aperture [Hz] * 360
GD [s] =
(1)
Group delay uncertainty Is calculated from the specified phase uncertainty and from the aperture (for aperture see below): Phase uncertainty [deg] --------------------------------------- *sqrt(2) Aperture [Hz] * 360
GD [s] =
(2)
Aperture Determined by the frequency span and the number of points per sweep Aperture: (frequency span) / (number of points-1)
GD Range The maximum group delay is limited to measuring no more than 180 degrees of phase change within the selected aperture (see Equation 1).
www..com
14
General Characteristics
Assembled dimensions: (H x W x D) 37.1 cm x 43.8 cm x 47.3 cm, (12.5 in x 17.3 in x 18.7 in) Weight Product net weight: 27.3 kg ( lbs) Packaged product: 47.3 kg (104.3 lbs) Power Requirements 90 to 132 V AC, or 198 to 264V AC Automatic switched 47 to 63 Hz 2 power cables E5071C Optical test set:
Shipping contents 1x Network-analyzer E5071C-245 1x N4374B optical test set 3x 81000 NI optical adapter 1x 4374B-90A01 Getting started 1x 4373B-90CD1 LCA support CD 1x 1150-7896 Keyboard 1x 1150-7799 Mouse 1x 8121-1242 USB cable 1x E5525-10285 UK6 report 2x 8120-8862 N-type male-male RF cable (0.5m) 1x 9320-6677 RoHS addendum for Photonic accessories 1x 9320-6654 RoHS addendum for Photonic T&M products 1x 11852B-CFG001 Minimum loss pad Additional, option dependent shipping contents: -021 straight connector: 2x N4373-87907 0.5m FC/APC to FC/PC patch cord 1x 1005-0256 FC/PC feedthrough -022 angled connector: 2x N4373-87906 0.5m FC/APC to FC/APC patch cord 1x 1005-1027 FC/PC adapter for APC -050 external optical source input 1x PMF patchcord 1.0m FC/APC narrow key 1x 81000NI optical adapter FC LCA connector types at optical testset LCA electrical input Type N (f) LCA electrical output Type N (f) LCA optical input 1 9um single-mode angled [1], with Agilent universal adapter LCA optical input 2 9um single-mode angled [1], with Agilent universal adapter LCA optical output 9um single-mode angled[1], with Agilent universal adapter LCA external TX input 9um polarization maintaining (option -050 only) single-mode angled, with Agilent universal adapter
[1]
max. 350 VA max. 40 VA
Network analyzer Option 332 E5071C -245 Storage temperature range -40 C to +70 C Operating temperature range +5 C to +35 C Humidity 15 % to 80 % relative humidity, non-condensing Altitude (operating) 0 ... 2000 m Recommended re-calibration period 1 year
The optical test set always has angled connectors. Depending on the selected option (-012 straight, -022 angled) the appropriate jumper cable will be delivered. This jumper cable must always be used in front to the optical test set to protect the connectors at the optical test set
www..com
Laser Safety Information All laser sources listed above are classified as Class 1M according to IEC 60825 1 (2001). All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26.
15
Mechanical Outline Drawings, option -332, -362 (all dimensions in mm)
www..com
16
Ordering informations
The N4374B consists of an optical test set and an electrical network analyzer which are mechanically connected. To protect your network analyzer investment, Agilent offers the integration of an already owned ENA-C with the optical test set as listed below. All systems have 1 year warranty with the option to extend this to 3 or 5 years.
N4374B LCA ordering options Network-analyzer options N4374B - 332 Network-analyzer integration options N4374B - 362 Integration of customer ENC-C - E5071C -240,-245 - all other NWA call factory 4.5 GHz LCA based on E5071C -245 , including Bias-T
Optical wavelength options N4374B-100 N4374B-101 N4374B-102 Configuration independent options N4374B-010 N4374B-050 N4374B-021 N4374B-022 Service and Repair R1280A R1282A Required accessories ( to be ordered separtely ) 85092C 2 port electrical calibration module ( -00F & 00A recommended) 1 year Return-to-Agilent warranty extended to 3 or 5 years Agilent calibration up front support plan 3 or 5 year coverage Time domain option External optical source input Straight connector interface (external 0.5 m patch cord) Angled connector interface (external 0.5 m patch cord) 1310 nm source optical test set 1550 nm source optical test set 1310 nm and 1550 nm source optical test set
www..com
17
Agilent Email Updates
www.agilent.com/find/emailupdates
Remove all doubt
Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to:
www.agilent.com/find/removealldoubt
Get the latest information on the products and applications you select.
www.agilent.com www.agilent.com/find/add specific jumpstation here
For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at:
Agilent Direct
www.agilent.com/find/agilentdirect
www.agilent.com/find/contactus Americas Canada Latin America United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand
Quickly choose and use your test equipment solutions with confidence.
Agilent Open
(877) 894-4414 305 269 7500 (800) 829-4444
www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development.
1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008
Optical instruments online information
www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Optical test instruments
www.agilent.com/find/oct
Europe & Middle East Austria 01 36027 71571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700*
*0.125 /minute
Lightwave Component Analyzers
www.agilent.com/find/lca
Germany
07031 464 6333**
**0.14 /minute
Polarization solutions
www.agilent.com/find/pol
Spectral analysis products
www.agilent.com/find/octspectral
Electro-optical converters
www.agilent.com/find/ref
Optical test instruments accesories
www.agilent.com/find/octaccessories
Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus
Revised: July 17, 2008
Firmware and driver download
www..com
www.agilent.com/find/octfirmware
Product specifications and descriptions in this document subject to change without notice. (c) Agilent Technologies, Inc. 2008 Printed in USA, December 17th, 2008 5989-9115EN
Agilent photonic discussion forum
www.agilent.com/find/photonic_forum


▲Up To Search▲   

 
Price & Availability of N4374B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X